The Phone Repair Company
Locating open shields / open by ratio
Formula
C = A&B
D = Distance of section (resistive )
1. Isolate cable bonds at both ends of section.
2. Determine the resistive distance of the section by shorting a cable
pair using a digital Ohm meter, and converting to feet.
3. Record this length as “D” measurement
4. Go to one end of the cable section and using the open mode of the test
equipment , connect the tip conductor lead to the shield of the section
under test. Take the ring lead along with the ground lead of the
test equipment and connect to a good earth ground . This will be
measurement “A”
5. From the other end of the section under test, do the same thing as the
test in #4 and make
this measurement “B”.
6. By combining A & B this will give you “C”
Contact Jake if you have any questions.
Earth Grounding Telephone Equipment and Personal
Earth Grounding:
when used with twisted copper or aluminum telephone cable is to
protect Personal and equipment from lightning only.
“There is no problem in any twisted copper cable that cannot be
located in a timely manner and a solution found for the repair of such problem”
- John “Jake “Jacobsen
|