Power Influence Test
The pair:
- Must test clear of all resistance faults.
- Must not have any unbalance conduction.
- Must have good continuity.
- If a working pair the jumper in the central office must be
separated from the cable pair.
The ground used for the test.
- Test the ground source that will be used for the test with
a ground resistance test. (If no test is equipment is on the
work site hook ground lead to the power neutral.
The location to take the test.
- Take the test from the field end of the cable pair only.
The test information
- P/I power influence reading should be <80db
- Noise reading should be <20db.
- Balance reading should be >60db.
Contact Jake if you have any questions.