The Phone Repair Company

Testing for A/C Voltage on the Cable Pair

  • Using a digital VOM set it on A/C Voltage (a digital VOM should be used .A 2/10 difference between the tip and reading is a dig problem)
  • Test the tip side to ground and record the reading.
  • Test the ring side to ground and record the reading.
  • If the 2 readings have 2/10 difference in A/C voltage there is a problem on the pair. There could be a number of problems: resistant an, open one side, unbalance, etc.
  • Test the Tip to Ring You should see 0 A/C volits. The presence of any A/C voltage tip to ring shows that you have a bad pair.

Contact Jake if you have any questions.

“There is no problem in any twisted copper cable that cannot be located in a timely manner and a solution found for the repair of such problem” - John “Jake “Jacobsen