Measure for a Capacitance Open
Equipment
- Open fault locator (capacitance test )
Test
- Place the red lead on the ring wire.
- Place the black lead on the Tip wire.
- Place the green lead on the tested ground ( If you can not
test the ground then find the nearest power neutral and use
that as your ground )
- The tip and ring leads have to be on a single pair. They can
not be on two difference pairs
- Make the 3 tests and record the reading.
What can be done with the reading?
- The reading you received was a total of all the wires
attached to the test set.
- The ground lead hooked to no ground will reduce your
reading around 50%. If the ground lead is hooked to a
ground with height resistance, you will get a reading
based on the amount of resistance the untested
Ground has.
- If the test comes back with the Tip to Ground and
Ring to Ground measurements balanced and they are
longer then the Tip to Ring measurement indicates,
there is an open bond on the cable under test. ( this
look at the bond will only work when the test set is
set on air core cable regardless of the type of cable
under test)
- If you are testing air core cable and you find that
your reading is longer than the cable, you are
working’ You may have water in the sheath ( See
formula water in the cable)
Contact Jake if you have any questions.
“There is no problem in any twisted copper cable that cannot be
located in a timely manner and a solution found for the repair of such problem”